SHT2000 Temperature Humidity Hygrometer Thermostat Ac110-230V/Dc12V/24V Sensor

Specifics:
Condition: 100% Brand New
Product name: Intelligent temperature and humidity controller
Product Model: SHT-2000
Temperature measurement range: -20-60℃
Humidity measurement range: 0-110%RH
Power supply voltage: Ac110-230V/DC 12V/DC 24V
Power frequency: 50/60Hz
Temperature measurement accuracy: 0.3℃
Humidity measurement accuracy: 3%
Output Control: MAX10A

Setting method: Start value Setting method: Start value > stop value (the program automatically determines the working mode is cooling/dehumidifying mode)
Heating/cooling mode setting
Setting mode: setting (starting temperature): Press and hold the ▲ button to start the temperature flashing. Use ▲▼ key to set the starting temperature value.
Setting (stop temperature): Press and hold the ▼ button to stop the temperature flashing. Use ▲▼ to set the stop temperature value.

Heating use case: control the water heater, heat to 65 ° C to stop, the temperature drops back to 50 ° C and start heating again
The first step: heating mode, starting temperature Step 2: Press and hold the ▲ button to start the temperature flashing. Use ▲▼ to set the starting temperature to 50 °C.
Step 3: Press and hold the ▼ button to stop the temperature flashing. Set the stop temperature to 65 °C with ▲▼ keys, and the setting is completed!
Refrigeration use case: use in the farm, the fan is ventilated to 26 ° C to stop, the temperature is raised to 30 ° C and the ventilation is started again.
The first step: cooling mode, starting temperature > stop temperature
Step 2: Press and hold the ▲ button to start the temperature flashing. Use ▲▼ to set the starting temperature to 30 °C.
The third step: long press the ▼ button to stop the temperature flashing, set the stop temperature to 26 °C by ▲▼, the setting is completed!

Humidification/Dehumidification Mode Settings:
Setting (start humidity): Press and hold △ key to start the humidity value flashing. Set the humidity value by △ ▽ key. set
[Stop Humidity]: Press and hold △ key to stop the humidity value flashing, and set the humidity to stop by △ ▽ key value.

Humidification example: fresh supermarket humidification, control humidifier 50% RH began to humidify, humidified to 80% RH to stop humidification. Setup steps:
Step 1: Press and hold the △ button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 50% RH.
Step 2: Press and hold the ▽ button for 3 seconds to stop the humidity value flashing. Set the value to 80% RH. After the setting is completed, the button will be operated for 5 seconds without returning to the normal display state.

Dehumidification example: workshop control exhaust dehumidification system, humidity 70% RH starts dehumidification, humidity 40% RH stops dehumidification
Setup steps:
Step 1: Press and hold the △ button for 3 seconds to start the humidity value flashing, and set the starting humidity value to 40% RH.
Step 2: Press and hold the ▽ button for 3 seconds to stop the humidity value flashing, set the value to 70% RH, the setting is completed, the button does not operate for 5 seconds, and automatically returns to the normal display state.

Note:
1.Please allow 1-3mm difference due to manual measurement.
2.Due to the different monitor and light effect, the actual color of the item might be slightly different from the color showed on the pictures. Thank you!

Package Included:
1 x Temperature Controller.

German

SHT2000 Temperature-Humidity Hygrometer Thermostat AC110-230V/DC12V/24V Sensor

Special features:
Condition: 100% brand new
Product name: Intelligent temperature and humidity controller
Product model: SHT-2000
Temperature measuring range: -20-60℃
Humidity measuring range: 0-110% RH
Supply voltage: AC 110-230V/DC 12V/DC 24V
Mains frequency: 50/60 Hz
Temperature measurement accuracy: 0.3℃
Accuracy of humidity measurement: 3%
Output control: MAX10A

Setting method: Initial value Setting method: Initial value > Stop value (the program automatically determines that the operating mode is cooling/dehumidifying mode)
Setting the heating/cooling mode
Setting mode: Setting (starting temperature): Press and hold the ▲ button to make the temperature flash. Use the ▲▼ buttons to set the starting temperature value.
Setting (Stop Temperature): Press and hold the ▼ button to stop the temperature from flashing. Use ▲▼ to set the stop temperature value.

Heating use case: Control the water heater, heat up to 65°C, then stop; the temperature drops back to 50°C and restart the heating.
First step: Heating operation, starting temperature Step 2: Press and hold the ▲ button until the temperature flashes. Use ▲▼ to set the starting temperature to 50 °C.
Step 3: Press and hold the ▼ button to stop the temperature from flashing. Use the ▲▼ buttons to set the stop temperature to 65 °C, and the setting is complete!
Cold application example: Use in an agricultural operation, the fan ventilates up to 26 °C until it stops, the temperature is increased to 30 °C and the ventilation is restarted.
First step: Cooling operation, starting temperature > Stop temperature
Step 2: Press and hold the ▲ button until the temperature flashes. Use ▲▼ to set the starting temperature to 30 °C.
The third step: Press and hold the ▼ button to stop the temperature from flashing, set the stop temperature to 26 °C using ▲▼, the setting is complete!

Humidification/Dehumidification Mode Settings:
Setting (starting humidity): Press and hold the △ button to make the humidity value flash. Adjust the humidity value using the △ ▽ buttons.
[Stop humidity]: Press and hold the △ button to stop the humidity value from flashing, and adjust the humidity using the △ ▽ button until it stops.

Humidification example: Fresh market humidification, control humidifier started humidifying at 50% relative humidity, humidified to 80% relative humidity to stop humidification. Setup steps:
Step 1: Press and hold the △ button for 3 seconds to make the humidity value start flashing, and set the initial humidity value to 50% relative humidity.
Step 2: Press and hold the ▽ button for 3 seconds to stop the humidity reading from flashing. Set the value to 80% relative humidity. Once the setting is complete, the button will remain pressed for 5 seconds without returning to the normal display state.

Dehumidification example: Workshop control system for exhaust gas dehumidification; dehumidification starts at 70% RH, and stops at 40% RH.
Setup steps:
Step 1: Press and hold the △ button for 3 seconds to make the humidity value start flashing, and set the initial humidity value to 40% relative humidity.
Step 2: Press and hold the ▽ button for 3 seconds to stop the humidity value from flashing, set the value to 70% RH, the setting is complete, the button will not work for 5 seconds and will automatically return to the normal display state.

Note:
1. Please allow 1-3 mm difference due to manual measurement.
2. Due to different monitor and lighting effects, the actual color of the item may differ slightly from the color shown in the pictures. Thank you!

Package contents:
1 x temperature controller.


Guarantee:

Returns: Customers have the right to request a return within 60 days of receiving the product.

24-hour online expert support: Solve your installation and product problems



You can also like

Last viewed